Maintenance
Controller Fault Codes
LED
CODE
PROGRAMMER LCD
DISPLAY
EXPLANATION POSSIBLE CAUSE
1,1 THERMAL CUTBACK
over-/under-temperature
cutback
1. Temperature >92°C or < -25°C.
2. Excessive load on vehicle.
3. Operation in extreme environments.
4. Electromagnetic brake not releasing.
1,2 THROTTLE FAULT 1 throttle fault
1. Throttle input wire open or shorted.
2. Throttle pot defective.
3. Wrong throttle type selected.
1,3 SPD LIMIT POT FAULT speed limit pot fault
1. Speed limit pot wire(s) broken or shorted.
2. Broken speed limit pot.
1,4 LOW BATTERY VOLTAGE battery voltage too low
1. Battery voltage >17 volts.
2. Bad connection at battery or controller.
1,5 OVERVOLTAGE battery voltage too high
1. Battery voltage>36 volts.
2. Vehicle operating with charger attached.
3. Intermittent battery connection.
2,1 MAIN OFF FAULT
main contactor driver Off
fault
1. Main contactor driver failed open.
2,3 MAIN CONT FLTS main contactor fault
1.Main contactor welded or stuck open.
2. Main contactor driver fault.
3. Brake coil resistance too high.
2,4 MAIN ON FAULT
main contactor driver On
fault
1. Main contactor driver failed closed.