CONTROLS
QTFSG/QTFSD 98349 05/15/03
3-2
The weighted root mean square acceleration at the
operator’s arms was measured to be below 2.5m/s
2
for
the QTFSG and below 3.2m/s
2
for the QTFSD. The
weighted root mean square acceleration at the
operator’s posterior was measured to be below 0.5m/s
2
for the QTFSG and below 1.3m/s
2
for the QTFSD. This
was a tri-axial, third-octave-band measurement made
during normal operation on a composite tile floor. The
measurement and related calculations were made in
accordance with ANSI S3.34-1986.
SPECIAL NOTES:
The sound pressure level at the operator’s ear was
measured to be 78 dBA for the QTFSG and 83 dBA for
the QTFSD. This was a nearfield, broad-band
measurement made during normal operation on a
composite tile floor with a white pad. This appliance
contains no possible source of impact noise. The
instantaneous sound pressure level is below 63 Pa.